In pathology departments, every grossing procedure carries two critical requirements: diagnostic accuracy and operator safety. However, traditional grossing tables often fall short—poor fume control, limited ergonomics, inefficient workflows, and outdated layouts increase health risks and reduce productivity.
Our Pathology Workstation solution is purpose-built to solve these challenges. Designed as a fully integrated, height-adjustable grossing station, it combines intelligent ventilation, formaldehyde management, ergonomic control, and modular configuration into a single, professional workstation—engineered for today’s high-demand pathology laboratories.

Designed for What Matters Most in Pathology Labs
This Pathology Workstation is not just equipment—it is a workflow solution. Every component shown in the solution diagram is positioned to support cleaner air, safer handling, and smoother daily operation.
✔ Advanced Fume Control & Air Management
An optimized airflow design integrates:
High-performance exhaust fan
Detachable exhaust outlet
Dedicated fresh air intake
Together, they create effective negative-pressure control, rapidly capturing formaldehyde vapors and biological aerosols at the source—helping laboratories meet occupational health and safety expectations.
✔ Intelligent Formaldehyde Handling
Formaldehyde exposure is one of the biggest risks in grossing rooms. This workstation minimizes that risk through:
Dedicated formaldehyde faucet
Formaldehyde supply and recovery system
Integrated formaldehyde recovery tank
This closed-loop approach significantly reduces vapor release and improves chemical management compliance.
✔ Ergonomic, Height-Adjustable Operation
Long hours of grossing work demand ergonomic solutions. This Pathology Workstation features:
Foot-controlled height adjustment
Hands-free tabletop nozzle foot switch
Optimized working zone dimensions
Operators can work comfortably whether seated or standing, reducing fatigue and long-term musculoskeletal strain.
✔ Clean, Safe, and Efficient Working Environment
To support precision work and daily disinfection:
LED flat panel lighting delivers uniform, shadow-free illumination
UV sterilization lamp enhances biosafety after use
Tempered glass panels improve visibility while maintaining enclosure integrity
These features create a clean, controlled environment that supports both accuracy and hygiene.
Built for Durability and Long-Term Value
The workstation is constructed primarily from SUS304 brushed stainless steel, with optional SUS201 configurations. This ensures:
Excellent corrosion resistance
Easy cleaning and disinfection
Long service life in high-use laboratory environments
The modular structure allows laboratories to adapt or upgrade components as workflow requirements evolve.
Smart Control, Simple Operation
At the heart of the system is a 7-inch touchscreen control panel with microcomputer control, enabling centralized operation of:
Ventilation system
Tissue crusher
Formaldehyde supply
Lighting and auxiliary functions
This intuitive interface simplifies daily operation and reduces training time for staff.
Ideal Applications
This Pathology Workstation is widely used in:
Hospital pathology grossing rooms
Forensic and autopsy laboratories
Medical school teaching labs
Why Choose Our Pathology Workstation?
Designed specifically for pathology workflows – not adapted from general lab furniture
Integrated safety-first design – formaldehyde control, ventilation, and UV disinfection
Ergonomic and intelligent – built for long working hours and high efficiency
Customizable and scalable – adaptable to different lab sizes and standards
Build a Safer, Smarter Grossing Room
A modern pathology lab deserves more than a basic table. It needs a Pathology Workstation that protects staff, enhances efficiency, and reflects professional standards.
If you are planning a new pathology laboratory or upgrading an existing grossing room, our team can provide custom layout design, solution diagrams, and configuration recommendations tailored to your workflow.
Contact us today to receive a customized Pathology Workstation solution for your laboratory.
Frequently Asked Questions
What are the different types of pathology grossing stations?
Grossing stations range from basic stainless steel workstations to advanced intelligent systems with touchscreen controls, formalin filling, and real-time environmental monitoring. The main types include basic models, height-adjustable stations, and smart digital systems. Types of Grossing Stations
How do I choose the right size grossing station for my laboratory?
The right size depends on your daily specimen volume, available lab space, and whether the station will be used by one or two operators. Standard widths range from 1500mm (single person) to 2200mm (double person). Grossing Station Selection Guide
What is the price range for a pathology grossing station?
Grossing station prices vary widely based on features, size, and configuration. Basic models are more affordable, while advanced intelligent stations with formalin filling systems and touchscreen controls command a higher investment. Grossing Station Price Guide
How to clean and maintain a pathology grossing station?
Regular cleaning and maintenance are essential for safety and longevity. Daily wipe-down of work surfaces, weekly inspection of the ventilation system, and periodic calibration of the UV sterilization lamp are recommended practices. Grossing Station Maintenance Guide
How to minimize formaldehyde exposure in pathology labs?
Minimize formaldehyde exposure through proper ventilation, formalin filling systems, down-draft exhaust on grossing stations, personal protective equipment, and regular air quality monitoring. Formaldehyde Exposure Guide
坤灵最新logo-scaled-1.png)